Eaton Moeller series xPole (Style 5) – mMC4/6/M MCB Technical
GENERAL SPECIFICATIONS
PRODUCT NAME
CATALOG NUMBER
EAN
PRODUCT LENGTH/DEPTH
PRODUCT HEIGHT
PRODUCT WIDTH
PRODUCT WEIGHT
COMPLIANCES
MODEL CODE
PRODUCT SPECIFICATIONS
RATED OPERATIONAL CURRENT FOR SPECIFIED HEAT DISSIPATION (IN)
RATED SHORT-CIRCUIT BREAKING CAPACITY (EN 60898) AT 230 V
MOUNTING METHOD
CURRENT LIMITING CLASS
RATED SHORT-CIRCUIT BREAKING CAPACITY (EN 60898) AT 400 V
AMPERAGE RATING
FREQUENCY RATING - MAX
FITTED WITH:
RATED SHORT-CIRCUIT BREAKING CAPACITY (IEC 60947-2) AT 400 V
NUMBER OF POLES (TOTAL)
TERMINAL PROTECTION
RATED SHORT-CIRCUIT BREAKING CAPACITY (IEC 60947-2) AT 230 V
SPECIAL FEATURES
AMBIENT OPERATING TEMPERATURE - MAX
HEAT DISSIPATION PER POLE, CURRENT-DEPENDENT
BUILT-IN DEPTH
RATED SWITCHING CAPACITY (IEC/EN 60898-1)
FEATURES
LIFESPAN, ELECTRICAL
CONNECTABLE CONDUCTOR CROSS SECTION (SOLID-CORE) - MIN
CONNECTABLE CONDUCTOR CROSS SECTION (SOLID-CORE) - MIN
CONNECTABLE CONDUCTOR CROSS SECTION (SOLID-CORE) - MIN
AMBIENT OPERATING TEMPERATURE - MIN
USED WITH
EQUIPMENT HEAT DISSIPATION, CURRENT-DEPENDENT
TRIPPING CHARACTERISTIC
FREQUENCY RATING - MIN
STATIC HEAT DISSIPATION, NON-CURRENT-DEPENDENT
APPLICATION
VOLTAGE TYPE
NUMBER OF POLES (PROTECTED)
FRAME
SUITABLE FOR
TERMINALS (TOP AND BOTTOM)
HEAT DISSIPATION CAPACITY
RELEASE CHARACTERISTIC
WIDTH IN NUMBER OF MODULAR SPACINGS
BUSBAR MATERIAL THICKNESS
LIFESPAN, MECHANICAL
CONNECTABLE CONDUCTOR CROSS SECTION (SOLID-CORE) - MAX
DEGREE OF PROTECTION
OVERVOLTAGE CATEGORY
ACCESSORIES REQUIRED
POLLUTION DEGREE
CONNECTABLE CONDUCTOR CROSS SECTION (MULTI-WIRED) - MIN
RATED IMPULSE WITHSTAND VOLTAGE (UIMP)
CONNECTABLE CONDUCTOR CROSS SECTION (MULTI-WIRED) - MAX
TYPE
RATED OPERATIONAL VOLTAGE (UE) - MAX
RATED INSULATION VOLTAGE (UI)
Eaton Moeller series xPole (Style 5) - mMC4/6/M MCB
139400
4015081361793
85 mm
73 mm
70 mm
48 kg
RoHS conform
mMC4-C20/3N
20A
4.5 KA
Quick attachment with 3 latch positions for top-hat rail IEC/EN 60715
3
4.5 KA
20 A
60 HZ
Z-IS/SPE-1TE 274418
0 KA
A
Finger and hand touch safe, DGUV VS3, EN 50274
0 KA
Maximum operating temperature is 75 °C : Starting at 40 °C a 1°C increase results in a 0.5% linear reduction of current carrying capacity Tripping signal contact for subsequent installation ZP-NHK 248437
40 °C
0 W
70.5 mm
4.5 kA
Additional equipment possible
10000 operations
1.5 mm²
1.5 mm²
Three-pole + N
-25 °C
Z-FW/LP 248296 (Remote control and automatic switching device) Miniature circuit breaker mMC4
10.1 W
C
50 Hz
0 W
Switchgear for residential and commercial applications xPole - Switchgear for residential and commercial applications
AC
3
45 mm
Flush-mounted installation
Open mouthed/lift terminals
0 W
C
4
0.8 mm - 2 mm
20000 operations
35 mm²
IP20
III
ZP-IHK 286052
2
2 mm²
4 kV
16 mm²
Miniature circuit breaker mMC4
230 V
440 V
Overview
Technical
Resources
GENERAL SPECIFICATIONS PRODUCT NAMEEaton Moeller series xPole (Style 5) – mMC4/6/M MCB
CATALOG NUMBER139400
EAN4015081361793
PRODUCT LENGTH/DEPTH85 mm
PRODUCT HEIGHT73 mm
PRODUCT WIDTH70 mm
PRODUCT WEIGHT48 kg
COMPLIANCESRoHS conform
MODEL CODEmMC4-C20/3N
PRODUCT SPECIFICATIONS RATED OPERATIONAL CURRENT FOR SPECIFIED HEAT DISSIPATION (IN)20A
RATED SHORT-CIRCUIT BREAKING CAPACITY (EN 60898) AT 230 V4.5 KA
MOUNTING METHODQuick attachment with 3 latch positions for top-hat rail IEC/EN 60715
CURRENT LIMITING CLASS3
RATED SHORT-CIRCUIT BREAKING CAPACITY (EN 60898) AT 400 V4.5 KA
AMPERAGE RATING20 A
FREQUENCY RATING – MAX60 HZ
FITTED WITH:Z-IS/SPE-1TE 274418
RATED SHORT-CIRCUIT BREAKING CAPACITY (IEC 60947-2) AT 400 V0 KA
NUMBER OF POLES (TOTAL)A
TERMINAL PROTECTIONFinger and hand touch safe, DGUV VS3, EN 50274
RATED SHORT-CIRCUIT BREAKING CAPACITY (IEC 60947-2) AT 230 V0 KA
SPECIAL FEATURESMaximum operating temperature is 75 °C : Starting at 40 °C a 1°C increase results in a 0.5% linear reduction of current carrying capacity Tripping signal contact for subsequent installation ZP-NHK 248437
AMBIENT OPERATING TEMPERATURE – MAX40 °C
HEAT DISSIPATION PER POLE, CURRENT-DEPENDENT0 W
BUILT-IN DEPTH70.5 mm
RATED SWITCHING CAPACITY (IEC/EN 60898-1)4.5 kA
FEATURESAdditional equipment possible
LIFESPAN, ELECTRICAL10000 operations
CONNECTABLE CONDUCTOR CROSS SECTION (SOLID-CORE) – MIN1.5 mm²
CONNECTABLE CONDUCTOR CROSS SECTION (SOLID-CORE) – MIN1.5 mm²
CONNECTABLE CONDUCTOR CROSS SECTION (SOLID-CORE) – MINThree-pole + N
AMBIENT OPERATING TEMPERATURE – MIN-25 °C
USED WITHZ-FW/LP 248296 (Remote control and automatic switching device) Miniature circuit breaker mMC4
EQUIPMENT HEAT DISSIPATION, CURRENT-DEPENDENT10.1 W
TRIPPING CHARACTERISTICC
FREQUENCY RATING – MIN50 Hz
STATIC HEAT DISSIPATION, NON-CURRENT-DEPENDENT0 W
APPLICATIONSwitchgear for residential and commercial applications xPole – Switchgear for residential and commercial applications
VOLTAGE TYPEAC
NUMBER OF POLES (PROTECTED)3
FRAME45 mm
SUITABLE FORFlush-mounted installation
TERMINALS (TOP AND BOTTOM)Open mouthed/lift terminals
HEAT DISSIPATION CAPACITY0 W
RELEASE CHARACTERISTICC
WIDTH IN NUMBER OF MODULAR SPACINGS4
BUSBAR MATERIAL THICKNESS0.8 mm – 2 mm
LIFESPAN, MECHANICAL20000 operations
CONNECTABLE CONDUCTOR CROSS SECTION (SOLID-CORE) – MAX35 mm²
DEGREE OF PROTECTIONIP20
OVERVOLTAGE CATEGORYIII
ACCESSORIES REQUIREDZP-IHK 286052
POLLUTION DEGREE2
CONNECTABLE CONDUCTOR CROSS SECTION (MULTI-WIRED) – MIN2 mm²
RATED IMPULSE WITHSTAND VOLTAGE (UIMP)4 kV
CONNECTABLE CONDUCTOR CROSS SECTION (MULTI-WIRED) – MAX16 mm²
TYPEMiniature circuit breaker mMC4
RATED OPERATIONAL VOLTAGE (UE) – MAX230 V
RATED INSULATION VOLTAGE (UI)440 V
Resources